UT of Welds - Reference Level, DAC and Applying Acceptance Critiea
The video defines the Reference Level used for ultrasonic testing and its application to the acceptance criteria. An example is presented where the reference level or DAC is established on 10 % ID and OD notches and applied on two discontinuities A and B